{"id":7371,"date":"2026-10-02T08:30:46","date_gmt":"2026-10-02T01:30:46","guid":{"rendered":"https:\/\/www.tigerwatersolutions.id\/?p=7371"},"modified":"2026-10-02T08:30:46","modified_gmt":"2026-10-02T01:30:46","slug":"sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower","status":"publish","type":"post","link":"https:\/\/www.tigerwatersolutions.id\/id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/","title":{"rendered":"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Hampir semua listrik yang masuk ke server berubah menjadi panas. Sistem pendingin data center bertugas membuang panas itu dari ruang server ke luar gedung, tanpa henti, 24 jam sehari. Artikel ini menjelaskan komponen utamanya, dari unit di ruang server sampai cooling tower di atap, dan di mana air berperan.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Rantai pendinginan data center<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Panas berpindah melalui beberapa tahap:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Server memanaskan udara di ruang data (white space).<\/li>\n\n\n\n<li>Unit CRAC atau CRAH menyerap panas dari udara itu.<\/li>\n\n\n\n<li>Pada sistem CRAH, panas dibawa oleh air dingin (chilled water) ke chiller.<\/li>\n\n\n\n<li>Chiller membuang panas ke luar, lewat kondensor berpendingin udara atau lewat cooling tower.<\/li>\n\n\n\n<li>Cooling tower melepaskan panas ke atmosfer dengan menguapkan air.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Beda CRAC dan CRAH<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><td><strong>Aspek<\/strong><\/td><td><strong>CRAC (Computer Room Air Conditioner)<\/strong><\/td><td><strong>CRAH (Computer Room Air Handler)<\/strong><\/td><\/tr><\/thead><tbody><tr><td>Cara kerja<\/td><td>Kompresor dan refrigeran di dalam unit (ekspansi langsung)<\/td><td>Kipas dan koil yang dialiri air dingin dari chiller<\/td><\/tr><tr><td>Skala umum<\/td><td>Ruang server kecil sampai menengah<\/td><td>Data center menengah sampai hyperscale<\/td><\/tr><tr><td>Efisiensi<\/td><td>Lebih rendah pada skala besar<\/td><td>Lebih tinggi pada skala besar<\/td><\/tr><tr><td>Kebutuhan air<\/td><td>Tidak ada<\/td><td>Tidak langsung; bergantung pada jenis chiller<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Chiller air-cooled vs water-cooled<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Chiller air-cooled<\/strong> membuang panas langsung ke udara lewat kipas kondensor. Sistem ini hampir tidak memakai air, tetapi efisiensinya turun saat udara luar panas, seperti di iklim tropis Indonesia.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Chiller water-cooled<\/strong> membuang panas ke air kondensor, yang kemudian didinginkan di cooling tower. Sistem ini lebih hemat listrik, sehingga banyak dipilih untuk data center besar. Konsekuensinya, fasilitas membutuhkan pasokan make-up water yang terus-menerus.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Cooling tower dan make-up water<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Cooling tower mendinginkan air dengan menguapkan sebagian kecilnya. Air yang menguap, ditambah air yang dibuang (blowdown) untuk mengendalikan mineral, harus terus diganti. Untuk data center 10 MW, kebutuhannya bisa sekitar 24 m\u00b3 per jam (lihat perhitungan di Berapa Banyak Air yang Dibutuhkan Data Center? <em>(link: \/blog\/kebutuhan-air-data-center)<\/em>).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Cooling tower hibrida menggabungkan pendinginan kering dan basah. Pada cuaca sejuk bekerja lebih kering, sehingga pemakaian air turun. Digital Edge, misalnya, memakai chiller water-cooled dengan cooling tower hibrida di kampus CGK mereka di Cikarang.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Liquid cooling untuk server AI<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Server AI menghasilkan panas jauh lebih besar per rak. Karena itu liquid cooling (direct-to-chip) semakin umum: cairan pendingin dialirkan langsung ke pelat di atas prosesor. Kampus CGK4 milik BDx di Jawa Barat, misalnya, dirancang untuk hingga 500 kW per rak dengan direct-to-chip liquid cooling.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Liquid cooling tidak menghilangkan kebutuhan pembuangan panas. Panasnya tetap harus dibuang ke luar gedung, sering kali lewat cooling tower atau dry cooler.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Di mana tangki air berperan<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Cadangan make-up water.<\/strong> Umumnya untuk 12 jam pada data center Tier III dan Tier IV, dalam beberapa tangki agar satu bisa diservis.<\/li>\n\n\n\n<li><strong>Tangki thermal storage.<\/strong> Menyimpan air dingin agar pendinginan tetap berjalan beberapa menit saat chiller restart setelah gangguan listrik.<\/li>\n\n\n\n<li><strong>Tangki air pemadam kebakaran.<\/strong> Terpisah dari sistem pendingin.<\/li>\n\n\n\n<li><strong>Penampungan air hujan dan air daur ulang.<\/strong> Untuk menurunkan pemakaian air bersih.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Butuh tangki untuk sistem pendingin data center?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PT Tiger Water Solutions memproduksi tangki GFS, bolted steel dan panel FRP untuk cadangan make-up water, air pemadam dan air daur ulang, serta sistem pengolahan air (WTP). Pabrik kami di Cikarang melayani proyek data center di Bekasi, Karawang dan sekitarnya.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower Hampir semua listrik yang masuk ke server berubah menjadi panas. Sistem pendingin data center bertugas membuang panas itu dari ruang server ke luar gedung, tanpa henti, 24 jam sehari. Artikel ini menjelaskan komponen utamanya, dari unit di ruang server sampai cooling tower di atap, dan &#8230; <a title=\"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower\" class=\"read-more\" href=\"https:\/\/www.tigerwatersolutions.id\/id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\" aria-label=\"Baca selengkapnya tentang Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower\">Baca Selengkapnya<\/a><\/p>","protected":false},"author":1,"featured_media":7377,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[31],"tags":[],"class_list":["post-7371","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-center"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.8 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Sistem Pendingin Data Center Cooling: CRAC, CRAH &amp; Chiller<\/title>\n<meta name=\"description\" content=\"Cara kerja sistem pendingin data center: beda CRAC dan CRAH, chiller air-cooled vs water-cooled, cooling tower, liquid cooling.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.tigerwatersolutions.id\/id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\" \/>\n<meta property=\"og:locale\" content=\"id_ID\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sistem Pendingin Data Center Cooling: CRAC, CRAH &amp; Chiller\" \/>\n<meta property=\"og:description\" content=\"Cara kerja sistem pendingin data center: beda CRAC dan CRAH, chiller air-cooled vs water-cooled, cooling tower, liquid cooling.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.tigerwatersolutions.id\/id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\" \/>\n<meta property=\"og:site_name\" content=\"PT Tiger Water Solutions\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-02T01:30:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"832\" \/>\n\t<meta property=\"og:image:height\" content=\"448\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Endy Gunawan\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Ditulis oleh\" \/>\n\t<meta name=\"twitter:data1\" content=\"Endy Gunawan\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimasi waktu membaca\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 menit\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\"},\"author\":{\"name\":\"Endy Gunawan\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#\/schema\/person\/6397dc16dd69b40374d6b05edee5480e\"},\"headline\":\"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower\",\"datePublished\":\"2026-10-02T01:30:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\"},\"wordCount\":525,\"publisher\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#organization\"},\"image\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg\",\"articleSection\":[\"Data Center\"],\"inLanguage\":\"id\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\",\"url\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\",\"name\":\"Sistem Pendingin Data Center Cooling: CRAC, CRAH & Chiller\",\"isPartOf\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg\",\"datePublished\":\"2026-10-02T01:30:46+00:00\",\"description\":\"Cara kerja sistem pendingin data center: beda CRAC dan CRAH, chiller air-cooled vs water-cooled, cooling tower, liquid cooling.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#breadcrumb\"},\"inLanguage\":\"id\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage\",\"url\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg\",\"contentUrl\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg\",\"width\":832,\"height\":448,\"caption\":\"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.tigerwatersolutions.id\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#website\",\"url\":\"https:\/\/www.tigerwatersolutions.id\/\",\"name\":\"PT Tiger Water Solutions\",\"description\":\"Reservior\",\"publisher\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.tigerwatersolutions.id\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"id\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#organization\",\"name\":\"PT Tiger Water Solutions\",\"url\":\"https:\/\/www.tigerwatersolutions.id\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2024\/11\/cropped-logo-tiger-water-solutions.jpg\",\"contentUrl\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2024\/11\/cropped-logo-tiger-water-solutions.jpg\",\"width\":1600,\"height\":574,\"caption\":\"PT Tiger Water Solutions\"},\"image\":{\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#\/schema\/person\/6397dc16dd69b40374d6b05edee5480e\",\"name\":\"Endy Gunawan\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"id\",\"@id\":\"https:\/\/www.tigerwatersolutions.id\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/litespeed\/avatar\/e9ac6e11bc3007c67f74ae69f7abcb2a.jpg?ver=1791781029\",\"contentUrl\":\"https:\/\/www.tigerwatersolutions.id\/wp-content\/litespeed\/avatar\/e9ac6e11bc3007c67f74ae69f7abcb2a.jpg?ver=1791781029\",\"caption\":\"Endy Gunawan\"},\"sameAs\":[\"https:\/\/www.tigerwatersolutions.id\"],\"url\":\"https:\/\/www.tigerwatersolutions.id\/id\/author\/twsadm\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sistem Pendingin Data Center Cooling: CRAC, CRAH & Chiller","description":"Cara kerja sistem pendingin data center: beda CRAC dan CRAH, chiller air-cooled vs water-cooled, cooling tower, liquid cooling.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.tigerwatersolutions.id\/id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/","og_locale":"id_ID","og_type":"article","og_title":"Sistem Pendingin Data Center Cooling: CRAC, CRAH & Chiller","og_description":"Cara kerja sistem pendingin data center: beda CRAC dan CRAH, chiller air-cooled vs water-cooled, cooling tower, liquid cooling.","og_url":"https:\/\/www.tigerwatersolutions.id\/id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/","og_site_name":"PT Tiger Water Solutions","article_published_time":"2026-10-02T01:30:46+00:00","og_image":[{"width":832,"height":448,"url":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg","type":"image\/jpeg"}],"author":"Endy Gunawan","twitter_card":"summary_large_image","twitter_misc":{"Ditulis oleh":"Endy Gunawan","Estimasi waktu membaca":"3 menit"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#article","isPartOf":{"@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/"},"author":{"name":"Endy Gunawan","@id":"https:\/\/www.tigerwatersolutions.id\/#\/schema\/person\/6397dc16dd69b40374d6b05edee5480e"},"headline":"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower","datePublished":"2026-10-02T01:30:46+00:00","mainEntityOfPage":{"@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/"},"wordCount":525,"publisher":{"@id":"https:\/\/www.tigerwatersolutions.id\/#organization"},"image":{"@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg","articleSection":["Data Center"],"inLanguage":"id"},{"@type":"WebPage","@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/","url":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/","name":"Sistem Pendingin Data Center Cooling: CRAC, CRAH & Chiller","isPartOf":{"@id":"https:\/\/www.tigerwatersolutions.id\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage"},"image":{"@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage"},"thumbnailUrl":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg","datePublished":"2026-10-02T01:30:46+00:00","description":"Cara kerja sistem pendingin data center: beda CRAC dan CRAH, chiller air-cooled vs water-cooled, cooling tower, liquid cooling.","breadcrumb":{"@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#breadcrumb"},"inLanguage":"id","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/"]}]},{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#primaryimage","url":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg","contentUrl":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2026\/09\/12fb30f9-d7b4-4878-86fd-0026338c0c16.jpg","width":832,"height":448,"caption":"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower"},{"@type":"BreadcrumbList","@id":"https:\/\/www.tigerwatersolutions.id\/sistem-pendingin-data-center-crac-crah-chiller-dan-cooling-tower\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.tigerwatersolutions.id\/"},{"@type":"ListItem","position":2,"name":"Sistem Pendingin Data Center: CRAC, CRAH, Chiller dan Cooling Tower"}]},{"@type":"WebSite","@id":"https:\/\/www.tigerwatersolutions.id\/#website","url":"https:\/\/www.tigerwatersolutions.id\/","name":"PT Tiger Water Solutions","description":"Reservior","publisher":{"@id":"https:\/\/www.tigerwatersolutions.id\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.tigerwatersolutions.id\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"id"},{"@type":"Organization","@id":"https:\/\/www.tigerwatersolutions.id\/#organization","name":"PT Tiger Water Solutions","url":"https:\/\/www.tigerwatersolutions.id\/","logo":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.tigerwatersolutions.id\/#\/schema\/logo\/image\/","url":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2024\/11\/cropped-logo-tiger-water-solutions.jpg","contentUrl":"https:\/\/www.tigerwatersolutions.id\/wp-content\/uploads\/2024\/11\/cropped-logo-tiger-water-solutions.jpg","width":1600,"height":574,"caption":"PT Tiger Water Solutions"},"image":{"@id":"https:\/\/www.tigerwatersolutions.id\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.tigerwatersolutions.id\/#\/schema\/person\/6397dc16dd69b40374d6b05edee5480e","name":"Endy Gunawan","image":{"@type":"ImageObject","inLanguage":"id","@id":"https:\/\/www.tigerwatersolutions.id\/#\/schema\/person\/image\/","url":"https:\/\/www.tigerwatersolutions.id\/wp-content\/litespeed\/avatar\/e9ac6e11bc3007c67f74ae69f7abcb2a.jpg?ver=1791781029","contentUrl":"https:\/\/www.tigerwatersolutions.id\/wp-content\/litespeed\/avatar\/e9ac6e11bc3007c67f74ae69f7abcb2a.jpg?ver=1791781029","caption":"Endy Gunawan"},"sameAs":["https:\/\/www.tigerwatersolutions.id"],"url":"https:\/\/www.tigerwatersolutions.id\/id\/author\/twsadm\/"}]}},"_links":{"self":[{"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/posts\/7371","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/comments?post=7371"}],"version-history":[{"count":1,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/posts\/7371\/revisions"}],"predecessor-version":[{"id":7372,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/posts\/7371\/revisions\/7372"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/media\/7377"}],"wp:attachment":[{"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/media?parent=7371"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/categories?post=7371"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tigerwatersolutions.id\/id\/wp-json\/wp\/v2\/tags?post=7371"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}